Displaying report 1-1 of 1.
Reports until 13:01, Thursday 17 April 2014
H1 DAQ (CDS, DCS)
david.barker@LIGO.ORG - posted 13:01, Thursday 17 April 2014 - last comment - 13:03, Thursday 17 April 2014(11409)
DAQ restart, more h1fw1 problems

at 11:09 I restarted the DAQ to suport new INI files from the ISI model changes. All came back OK except h1fw1, which now could not write any frames.

12:27 I stopped h1fw1 daqd process and unmounted the NFS export from h1ldasgw1. I then power cycled h1ldasgw1

12:46 had problems getting the file system viewable again, did a reboot of h1ldasgw1.

12:55 Finally got h1fw1 writing again, had the to the following on h1ldasgw1

# mount /cds-h1-frames

# shareall

Lets see if the reboot of the Solaris QFS server restored h1fw1 to stability.

Comments related to this report
david.barker@LIGO.ORG - 13:03, Thursday 17 April 2014 (11410)

during this DAQ restart I added back the weather stations for EX and MY (H0EDCU_WEATHER.ini). Note the EX weather station is not working, the EPICS channels exist but have bogus values. This reconfiguration is in anticipation of getting this going again.

Displaying report 1-1 of 1.