alexan.staley@LIGO.ORG - posted 13:54, Thursday 17 April 2014 - last comment - 09:31, Friday 18 April 2014(11413)
ETMX ISI Tripped

Sheila switched the blends when the trilliums were still rung up.

Images attached to this report
Comments related to this report
brian.lantz@LIGO.ORG - 16:02, Thursday 17 April 2014 (11418)
was this using the new ramp code? that is less glitchy? 
hugo.paris@LIGO.ORG - 09:31, Friday 18 April 2014 (11430)

Yes, this was using the new ramp code but the trip has nothing to do with the ramping itself. The blends were just switched from Start (no T240) to TCrappy (with T240) while the Trilliums were still saturated, causing the ISI to trip on the actuators as soon as the T240s got into the blend.
 

Switching the blends after waiting for the Trilliums to quiet down, as recomended, worked perfectly fine.