J. Kissel Following the changes made yesterday, I've finished all H1 model changes for reducing false alarm Rate (ECR E1400102) complete in a similar fashion on the remaining HAM SUS, i.e. HLTS, HSTS (including MC_MASTERs, and unhooked pr2) OMCS, HSSS. Sadly all these reboots seemed to have crashed something with guardian, because it's failing to restore the ISIs, I couldn't get SR2 to recover (via guardian), the IMC is complaining that the PSL REFL PD has no light on it, and indeed there's no light seen on the REFL or TRANS cameras. Perhaps Beckhoff went down? I don't how to restart it, or I would. Regardless, I've brought all the SUS, ISIs, and HEPIs up and confirmed that all alignments are the same. Anyways, a fun investigation to get the week started right. However, barring bugs, this should close out ECR E1400102 for H1, and L1 can either wait for more ECRs to be complete, or update incrementally as they wish. I'll post some more details and screenshots tomorrow. Details: --------------------------------- h1dc0 was rebooted at 1082070016 2014-04-20 04:30 PDT 2014-04-20 23:00 UTC and all models touched report a clean DAQ status, with the both frame writers happily chugging. Files afected by these changes: ${userapps}/release/sus/common/models/ M OMCS_MASTER.mdl M HSSS_MASTER.mdl M HSTS_MASTER.mdl M FOUROSEM_STAGE_MASTER.mdl M HLTS_MASTER.mdl M SIXOSEM_F_STAGE_MASTER.mdl M SIXOSEM_T_STAGE_MASTER.mdl M MC_MASTER.mdl ${userapps}release/sus/h1/models/ M h1suspr2.mdl M h1susim.mdl M h1suhtts.mdl /opt/rtcds/userapps/release/sus/common/medm M medm/haux/SUS_CUST_HAUX_OVERVIEW_all.adl M medm/hsss/SUS_CUST_IM_DACKILL.adl M medm/hsss/SUS_CUST_HTTS_DACKILL.adl M medm/hsss/SUS_CUST_HSSS_M1_WD.adl M medm/omcs/SUS_CUST_OMCS_OVERVIEW.adl A medm/omcs/SUS_CUST_OMCS_WD.adl M medm/hxts/SUS_CUST_HLTS_OVERVIEW.adl M medm/hxts/SUS_CUST_HSTS_OVERVIEW.adl A medm/hxts/SUS_CUST_HXTS_WD.adl M medm/tmts/SUS_CUST_TMTS_WD.adl All of the above changes have now been committed to the userapps repository.