J. Kissel (Approved by M. Landry, K. Kawabe, V. Sandberg) I'm taking the opportunity while gate-valves are closed for TCS table moving to install ASC dither alignment IPC channels into all core-optic SUS, (see ECR ). This will replicate what has been done for PR2 (see LHO aLOG 10346). Note, for now (so the SUS models will compile without complaint), I plan to add the IPC sender channels at the top-level of the ASC model, with zeros sent into them, and I'll leave it up to the ISC team to hook them up to their main library block as they wish. The models affected with be (to add new IPC sender parts) h1asc (to add new IPC receiver parts) h1susprm h1suspr3 h1susbs h1susimty h1susitmx h1susetmx h1susetmy h1sussrm h1sussr2 h1sussr3 [because it uses the HSTS_MASTER, MC_MASTER library part, so new unused inputs must be terminated] h1susmc1 h1susmc2 h1susmc3 (to add dither paths to each stage of each SUS type) SIXOSEM_F_STAGE_MASTER FOUROSEM_STAGE_MASTER FOUROSEM_STAGE_MASTER_OPLEV SIXOSEM_T_STAGE_MASTER QUAD_MASTER BSFM_MASTER HLTS_MASTER HSTS_MASTER MC_MASTER Work beginning 1082304916 2014-04-23 16:15 UTC 2014-04-23 09:15a PDT I'll make sure to capture a new h1asc_safe.snap before getting started.