EY measurements

Today we were able to lock the y arm for a significant period of time. Here are some settings:

PDH REFL Servo Board:

I took a few measurements:

  1. Power at REFL A PD: 6.5mW
  2. PDH error signal peak to peak: 780mV
  3. PDH loop suppressed error signal (EY_PDH_NoiseSpecV.txt)
  4. OLTF: again the UGF was around 3kHz with a phase margin of 68deg (mag --> 125.txt, phase --> 126.txt)
  5. With ITMX misaligned, I measured the shot noise of REFL A (EY_PDH_ShotNoiseSpecV.txt) -- this noise is partially limited by the SR785 noise; this is not "pure shot noise"
  6. While blocking the PD, I measured the dark noise of REFL A (EY_PDH_DarkNoiseSpecV.txt) -- this noise is limited by the SR785 noise
Non-image files attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 19:40, Wednesday 23 April 2014 (11549)

Note: Stefan has since changed the input gain to -13dB and the fast gain to 6dB. The overall UGF and loop shape is the same. See alog 11547