Alexa, Sheila, Stefan Our goal today was to get a good diff readout going. For this we - Commissioned the IMTY and ETMY optical levers, See snapshot. - Recommissioned the x-arm dither - turns out the phases were tuned up for a different suspension setting - we need configuration control on all the suspension settings. Also see the snaphot. - With that we got fairly stable arm locking - at least for a while - see below. - Next we tweaked up the DIFF beat note on ISCT1. We got -20dB signal out of the PD. - Th PLL locked for short stretches, but essentially always runs out of range after a few seconds. - Thus we decided to work on top-mass slow feed-back: There was a lot of confusion, but once everything was done right, it sort of worked. - One thing we noticed along the way, is that our 1-3Hz BLRM traces pick up increases in noise with an roughly hourly periodicity. This noise somehow translates into extra length motion at 0.05Hz. - We also fine-tuned the ETMY top mass L2P filter - see Arnaud's log - The slow feed-back gain was however limited by our main suspension resonance, which meant that we couldn't suppress the DIFF motion enough. - We thus decided to work on the L2L filters, which should give us the ability to increase the UGF of that loop and get more suppression. - We got a simple L2L measurement going, but more work is needed.
Stefan tweaked the L2P decoupling filter to improve (even more!) the top mass to test mass length to pitch decoupling. Basically, the Q of the first resonance of the filter was reduced from 16 to 12.5, (see difference in the attached plots) and this helped reducing the pitch motion, while driving in length, by a factor of ~2. The new filter is loaded in the L2P M0 drivealign matrix bank, and named L2PQ12.5. The old filter is loaded in FM6 as L2P1legacy.