Displaying report 1-1 of 1.
Reports until 16:57, Friday 25 April 2014
H1 ISC
sheila.dwyer@LIGO.ORG - posted 16:57, Friday 25 April 2014 - last comment - 11:38, Monday 28 April 2014(11579)
ALS DIFF noise

Sheila, Alexa, Stefan, Daniel

Attached is a spectrum, in Hz/rt Hz, of the PLL control singals for ALS diff and COMM.  This looks simliar to what was measured at Livingston last week.

We made changes to the LSC model to route these control signals into the input matrix to allow us to lock ALS DIFF. 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 11:38, Monday 28 April 2014 (11600)

These are calibrated in Hz, the spectra plotted above.  The first column is frequency, the second is COMM ASD in HZ/rt Hz,the third DIFF ASD in Hz/rt Hz. 

Non-image files attached to this comment
Displaying report 1-1 of 1.