Displaying report 1-1 of 1.
Reports until 01:24, Wednesday 30 April 2014
H1 SUS
sheila.dwyer@LIGO.ORG - posted 01:24, Wednesday 30 April 2014 - last comment - 10:17, Wednesday 30 April 2014(11639)
ETMX L2L measurement for UIM

Kiwamu, Arnaud, Sheila

We spent this evening trying to get UIM to test mass length to length measurements.  We do this with no slow feedback to the top mass.  With optical lever damping on, we saturate the PUM at high frequencies, so it has been easier to make the measurements with OpLev damping off.  We have reasonable coherence from 5Hz down, saved as 2014-04-29_H1SUSETMX_L1_L2LPY_SwpetSine_OLDamp_Off_5Hz_to600mHz.xml

We are leaveing one measuremetn running on opsws6 with an envelope that we have tuned to get the low frequency part, saved as 2014-04-29_H1SUSETMX_L1_L2LPY_SwpetSine_OLDamp_Off_1Hz_down.xml.

We briefly tried using the UIM for feedback, with a theoretical plant inversion filter, with no obvious sucess. 

Kiwamu fixed the calibration of REFL_Y_CTRL, makiing it identical to REFL_X_CTRL. 

Images attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 08:57, Wednesday 30 April 2014 (11641)

The measurement is complete and I have saved the file.

sheila.dwyer@LIGO.ORG - 08:58, Wednesday 30 April 2014 (11642)

Images attached to this comment
arnaud.pele@LIGO.ORG - 10:17, Wednesday 30 April 2014 (11645)

I changed the gain of ALS-Y_REFL_CTRL back to 1 (as it is set for ALS-X)

Displaying report 1-1 of 1.