H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 19:43, Wednesday 30 April 2014 - last comment - 22:59, Wednesday 30 April 2014(11663)
CSD for LSC
- Stood up CSD for H1LSCAUX, H1LSC, and H1ECATC1PLC2.
- Updated the xml files for H1LSC and H1ECATC1PLC2 to handle ALS and PRMI states.
- In particular, for the purpose of setting its control state, I split the LSC in four separate systems:
  - The IMC part (H1:LSC-IMC_STATE)
  - The central interferometer part (H1:LSC-PRMI_STATE)
  - The ARMS & ALS part (H1:LSC-ARMS_STATE)
  - The photo diodes (H1:LSC-PD_STATE)
- The xml file easily allows to merge them later or add more / different states.
- The H1:LSC-PRMI_STATE variable currently can be set to PRX, PRY or PRMI
- In addition there is a H1:LSC-PRMI_PD_SELECT variable, which has values of VAC_PD, AIR_PD and 3f_PD.
- In addition I added
  - H1:LSC-MISC_STATE and H1:LSC-PSL_STATE for some additional junk.
  - H1:LSC-MATRIX_LOADING, which punches H1:LSC-PD_DOF_MTRX_LOAD_MATRIX if set to automatic (or does nothing in manual)

One Warning:
 - I spent some time trying to make sure that the H1ECATC1PLC2 does not interfere with guardian or Beckhoff auto-locking. But it is possible that I missed some channels (since there is no channel declaration available in either). So if we have issues tomorrow, we should set H1ECATC1PLC2 into dryop mode and watch for differences.

Comments related to this report
stefan.ballmer@LIGO.ORG - 22:59, Wednesday 30 April 2014 (11666)
I also updated the LSC guardian to make use of the CSD for the LSC.
Next I need to do the same for the ALS guardians.