Final alignment numbers for last weeks SR2 alignment (now that we have good TFs):
-
X axis position: -595.4 mm
-
Target: -594.2 mm
-
Error: -1.2 mm
-
Tolerance: ±5.1 mm
-
Y axis position: -4161.1 mm
-
Target: -4161.5 mm
-
Error: +0.4 mm
-
Tolerance: ±3.0 mm
-
Z axis position: -104.3 mm
-
Target: -104.7 mm
-
Error: +0.4 mm
-
Tolerance: ±3.4 mm
-
Pitch: 5 µrad up
-
Target: 0 µrad
-
Error: 5 µrad up
-
Tolerance: ±520 µrad
-
Yaw: 42.289 mrad CCW
-
Target: 42.169 mrad CCW
-
Error: 0.120 mrad CCW
-
Tolerance: ±0.820 mrad