SR2 open light values

The "in chamber" SR2 open light values are :

M1T1 25373 1.182 -12686
M1T2 26012 1.153 -13006
M1T3 24840 1.208 -12420
M1LF 30482 0.984 -15241
M1RT 24731 1.213 -12366
M1SD 25027 1.199 -12513

M2UL 24112 1.244 -12056
M2LL 26045 1.152 -13022
M2UR 23920 1.254 -11960
M2LR 25085 1.196 -12543

M3UL 24821 1.209 -12410
M3LL 24674 1.216 -12337
M3UR 23869 1.257 -11934
M3LR 23932 1.254 -11966

A new safe.snap was made and the spreadsheet E1200343 was updated

Comments related to this report
betsy.weaver@LIGO.ORG - 12:47, Tuesday 06 May 2014 (11730)

Note - I asked Arnaud to recheck these since we already had the lower stage OSEMs pulled back for the IAS alignment.  As well, I discovered that the top mass blade tip EQ stops are the rattle-loose kind so I need to now swap them in-chamber.  So, I pulled the top 6 BOSEMs off as well - a good time to recheck the OLV settings of all OSEMs.