betsy.weaver@LIGO.ORG - posted 14:27, Wednesday 07 May 2014 (11749)
HAM 4 status
In HAM 4, today I:
Replaced the 4 errant blade tip EQ stops (required use of tweezers) discovered yesterday.
Used the canning cone to spray FirstContact onto the SR2-HR surface in order to reinforce the thin sheet already on it. This is in prep for pulling the sheet later - it occurred to me to do this now since I am installing other HWS/Baffle items close to the SR2-HR and spraying FC later will require moving it all again.
Suspended the masses and rechecked with quick TF that chain is free of mechanical interference.
Reattached and realigned all 14 OSEMs in 6 DOFs, each.
Finished attaching and tightening balance of dog clamps to SR2.
Discovered that there is a missing cable table bracket.
Attached witness plate and 1" witness optic holder into places.
Set 1 of the HWS baffles in place on the table - cookie cutter didn't look quite right.
Set the SR2 AR baffle into place - again the cookie cutter didn't look at all right.
Set the SR2 Scraper baffle into place - same story, cookie cutter isn't quite right. Also, discovered I don't have the correct AOS washers which are used on the unique scraper baffle hold-down clamps.
Stopped to go figure out what the heck is up with the cookie cutters, and find specific washers.