h1asc model now compiling

Kiwamu and Dave

After the inclusion of the ADS (Alignment Dither System) part into ASC_MASTER.mdl the h1asc model would not compile. I spent some time this afternoon investigating this problem. I noticed that the rtdemod parts with were listed in the rcg error log all shared a from/goto tag call SPOP18 which was relatively new. When I removed these tags (10 receiver tags) and replaced with straight through connectors the model compiled.

On futher testing, I found the the addition of any more tags (even a single goto/from pair) caused the compile to fail. Perhaps we are seeing an internal part/tag limit.

I've attached the before and after pictures of the relevant part of ASC-ADS, the before has the yellow SPOP18 tags.

I've only performed a "make h1asc" at this point, if we choose to run this model a "make install-h1asc" will be needed. The ASC_MASTER was linking to an ASC_MASTERr7418.mdl file for the ADS block, I have broken this link and ingested ADS into the master model.