Z to RZ couplings

We are investigating the Z to RZ couplings that are currently limiting our ability to improve the Yaw isolation.

A measurement was performed on ITMY yesterdaty night. The unit was controlled with level 3 controlers and  high blend (T750mHz) in all 12 degrees of freedoms.

It has been driven at the Exc point of the Stage 1 Z isolation filter, therefore the drive was in [nm].  A white noise drive was used (filtered to put power on the low frequencies)

The plot attached shows the reponse of the inertial sensor. The top plot (Stage 1 T240s) are in [nm/s], [nrad/s] per unit of drive [nm]. The bottom plot (Stage 2 GS13s) are in [nm/s^3], [nrad/s^3] per unit of drive [nm].

The Z, RX, and RY response are as expected: slope goes as f, large main coupling,  cross coupling at sub-percent level...

X, and Y couplings are in high in the T240s, but suprinsingly the coherence is not very good.

As for RZ, which is the main focus of this measurement:

- the T240s show a 1/f slop that we assume is  due to magnetic couplings

- the GS13s shows the f^3 slope as expected, confirming the signal on the T240 is likely not real motion.

We have set up a measurement in the staging building to measure the direct coupling from one actuator to the T240s.

Images attached to this report
Comments related to this report
fabrice.matichard@LIGO.ORG - 09:31, Tuesday 13 May 2014 (11845)

Just started a similar measurement on ITMY, with all isolation loops off except Stage 1 Z and Stage 2 Z that is still on.

Jeff will stop the measurement when the maintenance adctivites start on this unit  (I will be in the staging building for the direct coupling measurement)

fabrice.matichard@LIGO.ORG - 11:51, Tuesday 13 May 2014 (11852)

Here are the results with only the Z loops engaged. The X and Y and couplings  are much higher, presumably because of higher tilt-coupling when the RX and RY isolation loops are off. The coupling with  all other degrees of freedoms is essentially unchanged.

 