H1 SUS ETMY UIM (L1) UR and LL Coil Driver Current Monitors Unresponsive
J. Kissel for S. Ballmer

Stefan noticed that the H1 SUS ETMY UIM (L1) UR and LL Coil Driver Current Monitors (specifically the FAST_IMON) 
H1:SUS-ETMY_L1_FASTIMON_LL_MON
H1:SUS-ETMY_L1_FASTIMON_UR_MON
are unresponsive to a DC offset. We should fix this.
Comments related to this report
arnaud.pele@LIGO.ORG - 12:46, Wednesday 14 May 2014 (11892)

For info : the only test that have been carried out yet (with Phil) to understand those non responsive channels was to measure the voltage between the monitor output and the anti aliasing chassis. For the 4 channels we saw a similar voltage readback increase when sending thousands counts, meaning the problem could come from anywhere from anti alias to model wiring. More details on the pb : here