Displaying report 1-1 of 1.
Reports until 14:11, Thursday 15 May 2014
H1 AOS
jason.oberling@LIGO.ORG - posted 14:11, Thursday 15 May 2014 - last comment - 08:46, Friday 16 May 2014(11917)
SRM Surrogate X, Y, Z Alignment Complete
IAS: J. Oberling
SUS: J. Bartlett
 
Took a first look at the SRM surrogate (SRM-s) today and lo-and-behold, no adjustment was necessary.  cool  The cookie cutters did their job and placed the suspension within spec for X, Y, and Z axis positions.  The position errors are below:

I have begun and mostly completed the setup for the rough pitch/yaw alignment of the SRM-s.  This will be completed tomorrow morning and the rough pitch/yaw alignment will follow.

Comments related to this report
betsy.weaver@LIGO.ORG - 16:29, Thursday 15 May 2014 (11923)

I ran quick V and R TFs and the sus looks healthy to me compared to old references that Arnaud left me.  I need to dig up a good L reference TF and run that in the morning, but then we should be good to go on the pitch/yaw tuning.

betsy.weaver@LIGO.ORG - 08:46, Friday 16 May 2014 (11934)

And L looks good, too!

Displaying report 1-1 of 1.