Reports until 09:10, Friday 16 May 2014
H1 SEI
jameson.rollins@LIGO.ORG - posted 09:10, Friday 16 May 2014 - last comment - 15:26, Saturday 17 May 2014(11936)
BS ISI stage 2 GS13 watchdog tripped

Came in this morning to find the BS ISI stage 2 GS13 watchdog tripped.  Unclear why.

The strange thing is that the trip appears to have occured at GPS 1084253752, which is 10:30pm last night, whereas commissioning finished up around 4:30am.  Did they just run with the BS tripped all night?

The watchdog was reset and guardian recovered everything fine.

Comments related to this report
sebastien.biscans@LIGO.ORG - 09:27, Friday 16 May 2014 (11938)

The ISI-BS is a little peculiar: we know that the Michelson feedback could send a kick to the ISI and trip ST2 watchdogs. It's very often that the commissioners work with ST2 tripped, and I wouldn't be surprised that's what happened last night.

Given that, you should double check with the crew to see if it was really the case.

jameson.rollins@LIGO.ORG - 15:26, Saturday 17 May 2014 (11953)

This was indeed the case.  The michelson lock was kicking the BS and tripping stage 2, so they just ran with it tripped.