G. Grabeel, D. Hosken, T. Vo

CO2X:
- Running all day today and last night, turned off at 23:25 UTC.
- Shipped out flipper mirrors and central heating masks for testing at CIT.

HWS:
- Visible laser alignment of the Y section of the HWS optics table complete up till the periscope, excluding the HWS.  
- Position sensors checked and working properly.
- X side of the table has all the optics mounted and we'll set them in place and align on Monday.

RH:
- ITMX RH is hooked up but the drive is about half as much as we request compared to ITMY.  We're investigating the possible causes now, the Beckhoff controls seem to be working alright.

Updated to latest MEDM SVN revisions to match LLOs recent changes.