3f + dual arm tonight: no real progress

Lisa, ChrisW, Jamie, Arnaud, Kiwamu

We locked the PRMI with the 1f signals at a CARM offset of 1-2 kHz. The goal is to hand it over to the 3f after the CARM offset passes approximately 1 kHz at which the arm cavities resonate with the 2f sidebands. However, we didn't get a real progress tonight. We will continue studying this configuration.

What we did:

Comments related to this report
lisa.barsotti@LIGO.ORG - 20:49, Saturday 17 May 2014 (11954)

"At some point, we noticed that the cavity stay locked without the slow feedback. So we stopped using the slow feedback."

There was high wind last night until around 2 am. Kiwamu's locking successes started when the wind stopped blowing. According to Robert's FOM, the wind was indeed pretty high, around 90% percentile..but still, I claim that we should be able to lock a cavity anyway.

We will try to produce meaningful plots, in the meantime here is the plot which has the times with high wind, as looking at the PEM EX SEIS BLRMS 1-3Hz.