Reports until 20:58, Saturday 17 May 2014
H1 PEM (PEM, SEI, SUS)
lisa.barsotti@LIGO.ORG - posted 20:58, Saturday 17 May 2014 - last comment - 22:26, Saturday 17 May 2014(11955)
Polarized seismic distrubance

Kiwamu, Jamie, Lisa

Today we had the illusion that we could start locking before dinner time, but that didn't happen.

While both the X and Y arms were locked on green, something happened in the corner station (visible in the PEM CS SEIS 30-100 mHz channels, especially Z) which affected only the Y arm, while the X arm remained happily locked.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 22:26, Saturday 17 May 2014 (11956)ISC

I added a very-low-frequency-boost in the BS oplev damping loop which reduces the motion between 10 mHz to 100 mHz.

When seismic was high as Lisa reported, BS also moved a lot in yaw by 1.5 urad in pk-pk. This was causing a power modulation in the ALS diff beatnote. So I added this filter to reduce the motion at very low frequencies. Also, I increased the gain for this loop from -0.03 to -0.05 as there was a servo instability at 1-ish Hz with the VLF boost engaged. When seismic is at the normal level, do not forget to disengage this VLF boost.