Here are the final alignment numbers for the SRM surrogate optic.
-
X axis: 303.8 mm
-
Target: 305.3 mm
-
Error: -1.5 mm
-
Tolerance: ±4.6 mm
-
Y axis: -19874.5 mm
-
Target: -19875.8 mm
-
Error: +1.3 mm
-
Tolerance: ±3.0 mm
-
Z axis: -113.6 mm
-
Target: -114.5 mm
-
Error: +0.9 mm
-
Tolerance: ±3.0 mm
-
Pitch: 545 µrad up
-
Target: 625 µrad up
-
Error: 80 µrad down
-
Tolerance: ±520 µrad
-
Yaw: 56.809 mrad CCW
-
Target: 57.119 mrad CCW
-
Error: 310 µrad CW
-
Tolerance: ±820 µrad