Low arm biuldup was due to misalignment in Y arm

This evening Lisa pointed out that the low carrier buildup can be explained by misalignment in the Y arm.

I spent an hour to carefully adjust the alignment. Indeed, after the alignment, I got a cavity flash of 45 (normalized for a single arm build up) which is the highest we ever obtained. Also, the funny REFL9I offset disappeared and I could see a PDH-looking signal there when CARM passed through a resonance.

What I did:

Comments related to this report
kiwamu.izumi@LIGO.ORG - 00:09, Friday 23 May 2014 (12041)

Also in the afternonn I did a simple, brief chek for the demod phase of all the REFL 1f PDs.

I swept the X arm through a resonance by using ALS comm and monitored the PDH signals. It seems that everyone is adjusted somewhat.

=== settings ===

REFL9 = 84.9 deg

REFL45 = 19.2 deg

REFLAIR9 = 90 deg

REFLAIR45 = 147.6 deg

The whitening gain for all the PDs was set to the maximum i.e. 45 dB in this measurement.

Images attached to this comment
lisa.barsotti@LIGO.ORG - 18:39, Friday 23 May 2014 (12068)

This is a summary of last week of locking work, for posterity.

https://dcc.ligo.org/LIGO-G1400576

Displaying report 1-1 of 1.