Displaying report 1-1 of 1.
Reports until 12:06, Friday 23 May 2014
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 12:06, Friday 23 May 2014 - last comment - 11:55, Tuesday 27 May 2014(12053)
ISS Oscillations (& Maybe Fixed?)

(Corey, Gerardo, Patrick)

Two days ago (about 4am Thurs morning) the ISS diffracted power started to drift down from about 6.7% down to 2.0%.  Once at 2%, it started to go into oscillations (roughly around 3am this morning); see attached 2-day trend.

Without instructions on how to address this (and no recent alogs noting this behavior), we scratched our heads a bit, moved some gains and hit buttons to no effect.  We returned back to the original state.  Then Patrick suggested we try switching from PD A to PD B, and this appeared to stop the oscillations.  It took us to a value of about 5%.  Unfortunately, it looks like the power is still sloping down however.  (Curious to see if the ISS goes back into oscillations at 9pm tonight).

Non-image files attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:55, Tuesday 27 May 2014 (12086)PSL

Actually switching PDs was not the way to go here; we generally want to stay with PD-A. 

So here, you want to adjust the REFSIGNAL (H1:PSL-ISS_REFSIGNAL) channel in 0.01 amounts.  With Rick on the phone, I went from -1.63 to -1.55.  This stablized the Diffracted Power and took it from ~2% up to ~10%.  