This morning, I:
- added the SR3 and SRM baffles to the HAM5 table and all of their dog clamps - I don't know why I didn't anticipate that the AOS cookie cutters for these were incorrect since I just went through this at HAM4, but they are. This time, I set all of the baffles in place according to the hole pattern on the table and the maps. I will get the cookie cutters modified to be correct, but at least the weight is on the table and roughly in the correct place.
- switched out the TFE stops on the SR3 - this was more involved than I anticipated since the 2" all metal/TFE stops were trapped by their own EQ stop bracket (chalk that one up to another #facepalm #poordesign). I ended up having to dissassemble the brackets somewhat in order to rotate them to get the old and new EQ stops to clear. We shoulda done this before putting it i the chamber - put the TFE was so nice during the move...
- added a vertical 3" wafer holder and a 1" horizontal witness plate holder to the table
- added the temperature cable and it's 8 brackets to the table - I did not lace the cable since there is still an open question on how I can do this better this time. It's bundled out of the way and is of negligable weight for SEI rebalancing.
- finished securing the cable routing.
- removed all tools/pans.
So, all payload is on the table and I've turned it over to SEI for balanceing/testing.