Removed 106kg from Stage1 including 20kg from Table top. Wall payload went from 125 to 40kg in addition to removing 2 10kg masses from table top. Lone table top mass at +X, -Y area gone, viton damping of Table Top masses still to go. When we balanced the table before any SUS went in, we had 810lbs on the table top (iLIGO & aLIGO stuff.) This was removed, table top balance mass added per D1001139, SUS adds SRs, OFI, & Baffles. Not sure what the projected payload was going to be on the table but this indicates it is 302kg. Sound good? Anyone care about how the mass distribution has changed? How about the poor distribution of the Table Top 1075s for damping?