Quad test stand centering screens fix

Jeff B reported that the OSEM speed-dial screens were not working on the QUAD test stand. A bit of poking showed that the sitemap1 alias invoked

/opt/rtcds/tst/x1/userapps/release/cds/x1/medm/X1SITEMAP.adl

The Display File field for the QUAD button on that screen invoked

/opt/rtcds/tst/x1/userapps/release/sus/x1/medm/quad/SUS_CUST_QUAD_OVERVIEW.adl

but the Arguments field included

SUSDIR=/opt/rtcds/tst/x1/cds_user_apps/trunk/sus/common/medm/quad

 

which references a newer set of files where all the speed-dials have been renamed from SUS_CUST_QUAD_M0_OSEM_ALIGN.adl and the like to SUS_CUST_QUAD_M0_CENTERING.adl etc.

 

I changed the SUSDIR and it now works. I also had to manually load the safe.snap file to get all the matrix elements and gains filled in.