Vibration Measurements of the beamtube
John Worden, R. Weiss
Vibration measurements of the beamtube with the new R10 insulation and aluminum jacket were made and described in the
appended document. The new insulation reduces the acoustic coupling to the beamtube but not as well as the initial insulation.
The data enables a more detailed estimate of the phase noise from the beamtube motion due to the faulty HR coatings of the new 
test mass mirrors. The DCC number of the document is T1400384.
Non-image files attached to this report
Comments related to this report
rainer.weiss@LIGO.ORG - 13:20, Thursday 05 June 2014 (12233)
Error in the document. Please see T1400384-v2 or LHO log entry 12232