EX WFSA beam clipping fixed

Yesterday Daniel noticed that the beam was clipped on EX WFSA, but the beam was not centered either and we were in the middle of IR beam finding. Today I centered the beam and it was still clipped because the beam was coming to the WFS head at much shallower angle than it should be. I fixed it by tilting the WFS head.