Reports until 13:23, Monday 15 August 2011
H2 SUS
robert.lane@LIGO.ORG - posted 13:23, Monday 15 August 2011 (1219)
Comment to the Comment to H2 SUS ITMY Reaction Chain Post Cabling (Click here to view original report: 1218 )
J. Kissel, R. Lane

Further investigation of the Transverse Mode Bifurcation continued. We went back and plotted the data of previous TFs, zoomed in just a little bit, to see if the Bifurcation was a result of the cabling, or if it had always been there.

Looking at the plot of the Trans to Trans TF below, it is clear that the bifurcation has always been there.
Non-image files attached to this report