Reports until 11:17, Wednesday 04 June 2014
H1 CDS
david.barker@LIGO.ORG - posted 11:17, Wednesday 04 June 2014 (12203)
new script to show model code SVN status

I have created a python script which shows the local SVN status for model code (mdl and c files used to build a model). It shows local mods and optionally shows any pending updates from the SVN repository.

The script is called reportTargetCodeStatus.py, give it -h or --help to show usage

david.barker@sysadmin0: reportTargetCodeStatus.py --help               

site is lho

usage: reportTargetCodeStatus.py [-h] [--showpending] targetname

 

Report status of all source code files associated with a given front end

target

 

positional arguments:

  targetname     the target to be reported

 

optional arguments:

  -h, --help     show this help message and exit

  --showpending  show code updates which are pending from the SVN repo

                 (requires kerberos ticket to be open)

 
here is an example run with --showpending (needs a local kerb ticket for ligo.org authentication) on the h1iscey model
 

david.barker@sysadmin0: reportTargetCodeStatus.py --showpending h1iscey

site is lho

                                                target:   h1iscey 

                                            showpending   Program will slow while contacting svn repostory 

                                   Model last compiled:   Tue Jun  3 10:52:58 2014 

                              Model compiled using RCG:   /opt/rtcds/rtscore/advLigoRTS-2.8.3

 

 

                                            source file             last modified svn_st Updates?

                          isc/common/models/LSC_END.mdl  Thu Nov 14 16:56:17 2013    -        -      

                        isc/common/models/STATECOMM.mdl  Thu Nov 14 16:08:57 2013    -        -      

                              isc/h1/models/h1iscey.mdl  Tue Apr 29 17:51:56 2014    -        -      

                 isc/common/models/FILTBANK_TRIGGER.mdl  Thu Nov 14 14:58:37 2013    -        -      

                                  cds/common/src/wait.c  Thu Apr 25 13:34:28 2013    -        -      

                          isc/common/models/ASC_END.mdl  Thu Nov 14 16:56:17 2013    -        -      

                   cds/common/models/SCHMITTTRIGGER.mdl  Thu Nov 14 14:50:26 2013    -        -      

                    cds/common/models/FILTBANK_MASK.mdl  Thu Nov 14 14:50:26 2013    -        -      

                      isc/common/models/LSC_TRIGGER.mdl  Thu Nov 14 14:58:38 2013    -        U      

                              isc/common/models/QPD.mdl  Tue Mar  4 09:42:07 2014    -        -      

                          isc/common/models/ALS_END.mdl  Tue Apr 29 09:52:21 2014    -        U      

                              isc/common/models/WFS.mdl  Wed Dec 11 19:13:12 2013    -        -      

                       isc/common/src/RtCommunication.c  Thu Nov 14 13:19:02 2013    -        -