Staging building SEI test stand down

It appears the hard drive for the /frames files has failed on seiteststand2.  The test stand will be down until a replacement can be installed.

Comments related to this report
james.batch@LIGO.ORG - 12:51, Thursday 05 June 2014 (12231)CDS

A new disk has been installed.  The IOP and x1isiitmx models have been restarted and frames are being written.  Historical trend data is not available.  The test stand should be ready to use.