Kyle, Gerardo - Vented Vertex and HAM6 volumes. Venting very slow -> Discovered too large of a pressure drop across desicant tower after-filter. Replaced filter element. Filter was clogged with activated alumina powder from desicant. Flow seemed normal for an hour or so then seemed to fall off again. -> Rechecked pressure drop across after-filter-normal. Replaced next downstream filter element (activated carbon element). This filter didn't look clogged but replaced anyway -> No Help. Flow seems to be restriced or excessive demand from LVEA. Output 0.2 psi (normal is > 0.5 psi). -> Double checked point-of-use butterfly valves in LVEA and walked down Class 100 air heade. Noted that receiver tank which supplies the drying tower stays in nominal 80 -120 psi range and that compressor duty cycle is normal. In-chamber work taking place and don't want to shut off purge air at this time. Will continue trouble shooting when purge air can be shut-down.