Corey, Dan, Jeff B, Keita, Sheila
DOCUMENTATION REDLINES
During the HAM6 work from last week, we all noted variances, missing info, errors in documentation as we went. Just wanted to post my specific list of items I came across.
D1300122: HAM6 Cable Harness Routing Configutation
D1000342: ISC HAM6 Assembly
PHOTOS
All photos of installation are in ResourceSpace, here.
Highlights of the work are attached to this alog. Take special note of the scratches which were observed on a QPD (photos #7 & 8).
CABLING SPREADSHEET
To the best of my ability I made a spreadsheet noting cable serial numbers and where they were used in HAM6. As noted earlier, the OMC cables were handled at CIT, and I was not able to note their s/n's. Also, the OMC PZT in-air cable is not connected to the chamber, so it is not noted. I do make note of the OMC CB floor discrepency noted above, as well as the switch of cables from D5 to D3. Here is the HAM6 Cable Table:
| IN-AIR CABLE | CHAMBER FEED-THRU | SR CABLES | CABLE BRACKET | IN-VAC CABLE | OMC CB | IN-VAC COMPONENT |
|---|---|---|---|---|---|---|
| CAB_H1:ISC_307 | D6-F1 | D1000225s/nS1106784 | .. | D1300369s/n?? | CB1, 2nd Floor | DC PD preamps, OMC |
| .. | D6-F2 | D1000225s/nS1106832 | .. | D1300376s/n?? | CB1, 1st Floor | PZTs, OMC |
| CAB_H1:ISC_404 | D6-F3 | D1000225s/nS1106829 | .. | D1300373s/n?? | CB2, 1st Floor | DC QPD, OMC |
| CAB_H1:ISC_232 | D6-F4 | D1000225s/nS1106780 | CB5, 2ND | D1101654s/nS1108061 | .. | QPD A/B |
| CAB_H1:ISC_235 | D6-F6 | D1000223s/nS1202641 | CB5, 1ST | D1000238s/nS1105053 | .. | OMC PICO |
| CAB_H1:ISC_236 | D6-F10 | D1000225s/nS1106728 | .. | D1000228s/nS1105236 | .. | Tip Tilt #1 |
| CAB_H1:ISC_317 | D6-F8 | D1000223s/nS1202649 | CB3, 1ST | D1000237s/nS1202732 | .. | BDV1 |
| CAB_H1:ISC_316 | D6-F9 | D1000223s/nS1202652 | CB3, 2ND | D1000237s/nS1202730 | .. | BDV2 |
| CAB_H1:ISC_234 | D6-F7 | D1000223s/nS1202643 | CB4, 1ST | D1000238s/nS1105220 | .. | ASC_C Picomotors |
| CAB_H1:ISC_233 | D6-F5 | D1000225s/nS1106785 | CB4, 2ND | D1101654s/nS1202409 | .. | ASC_C_DC QPD |
| CAB_H1:ISC_238 | D6-F12 | D1000225s/nS1106830 | .. | D1000228s/nS1105241 | .. | Tip Tilt#2 (really #3!) |
| H1:ISC_RF-26B | D5-1D1 | D1300278s/nS1301448 | .. | .. | .. | WFS-A rf |
| H1:ISC_RF-27B | D5-1D2 | D1300278s/nS1301451 | .. | .. | .. | WFS-A rf |
| CAB_H1:ISC_265 | D5-3C1-->D3-2C1!! | D1000225s/nS1106835 | .. | .. | .. | WFS-A |
| H1:ISC_RF-28B | D5-2D1 | D1300278s/nS1301449 | .. | .. | .. | WFS-B rf |
| H1:ISC_RF-29B | D5-2D2 | D1300278s/nS1301453 | .. | .. | .. | WFS-B rf |
| CAB_H1:ISC_266 | D5-3C2-->D3-2C2!! | D1000225s/nS1106833 | .. | .. | .. | WFS-B |
| CAB_H1:ISC_237 | D6-F11 | D1000225s/nS1106834 | .. | D1000228s/nS1105239 | Tip Tilt#3 (really #2) | |
| H1:SUS_HAM6-10 | D3-1C1 | D1000225s/nS1106791 | .. | D1000234s/n?? | CB2, 2nd | SUS OMC |
| H1:SUS_HAM6-11 | D3-1C2 | D1000225s/nS1106831 | .. | D1000234s/n?? | CB2, 3rd | SUS OMC |