Reports until 07:31, Thursday 12 June 2014
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 07:31, Thursday 12 June 2014 (12328)
CDS model and DAQ restart report, Wednesday 11th June 2014

model restarts logged for Wed 11/Jun/2014
2014_06_11 18:11 h1ioppemmx
2014_06_11 18:11 h1ioppemmy
2014_06_11 18:11 h1pemmx
2014_06_11 18:11 h1pemmy

2014_06_11 18:42 h1iopasc0
2014_06_11 18:43 h1iopasc0
2014_06_11 18:50 h1asc
2014_06_11 18:50 h1susauxasc0
2014_06_11 18:51 h1ascimc
2014_06_11 18:51 h1iopasc0
2014_06_11 18:51 h1ioppemmy
2014_06_11 18:51 h1sushtts
2014_06_11 18:57 h1ioplsc0
2014_06_11 18:57 h1lscaux
2014_06_11 18:57 h1lsc
2014_06_11 18:57 h1omc

2014_06_11 19:10 h1iopsusey
2014_06_11 19:12 h1susetmy
2014_06_11 19:12 h1sustmsy

Red are unexpected restarts at the time of power glitch. Purple restarting frozen models. Green fixing SWWD.