J. Kissel Dither paths, which had been added to the front end models a long time ago (see LHO aLOG 11627), have now been added to the QUAD overview screens. Not really much more to say that; It took a long time because squeezing the new banks in took a lot of rearranging and making things smaller. It was really exciting. I can't wait to do every other suspension. Stay on the edge of your seat. For Stuart -- because we're still prototyping the more complete ESD linearization routine, I've reverted the screen to what's in the repository, and added dither paths to *that*, committed, and then re-added the prototype linearization stuff. I updated: /opt/rtcds/userapps/release/sus/common/medm/quad/ SUS_CUST_QUAD_OVERVIEW.adl and there's some new screens (in the same folder): SUS_CUST_QUAD_DITHER2EUL.adl SUS_CUST_QUAD_DITHERINF.adl SUS_CUST_QUAD_L1_DITHER.adl SUS_CUST_QUAD_L2_DITHER.adl SUS_CUST_QUAD_L3_DITHER.adl SUS_CUST_QUAD_M0_DITHER.adl