Per bugzilla integration issue 463, looked at AA/AI chassis to verify units have the proper insulating film used to isolate the -15V regulators to the chassis metal wall. All AA/AI chassis at EX have been modified or verified to have the appropriate insulating film. SUS S1100321 S1105306 S1105295 S1103819 S1202273 S1202611 S1202819 S1202612 S1202820 SEI S1300132 S1300135 S1300136 S1300140 S1300144 S1300611 ISC (including Whitening chassis) S1102763 S1102781 S1102777 S1101606 S1101587 S1101631 S1101642 All electronics have been reconnected and powered up. All units were placed back in appropriate rack and slot location. Filiberto Clara