david.barker@LIGO.ORG - posted 11:30, Monday 23 June 2014 - last comment - 15:40, Monday 23 June 2014(12448)
SUS ETMY HWWD work
Jim and Dave. We are now running a HWWD version of h1susetmy compiled against branch2.8. The model was restarted at 11:16PDT. If we determine there is an error with channel 25 of the binary output chassis, we will replace that chassis.
Comments related to this report
david.barker@LIGO.ORG - 15:40, Monday 23 June 2014 (12453)
We determined that this was not a hardware problem. I removed an EPICS-OUTPUT part between the HWWD and the delay part in h1susetmy and we were able to control the HWWD. So no binary chassis change at EY and we are able to control the HWWD. Unfortunately when I re-installed the epics part the communication continued to work, so we are not able to reproduce the problem.
We determined that this was not a hardware problem. I removed an EPICS-OUTPUT part between the HWWD and the delay part in h1susetmy and we were able to control the HWWD. So no binary chassis change at EY and we are able to control the HWWD. Unfortunately when I re-installed the epics part the communication continued to work, so we are not able to reproduce the problem.