ODC and iso gains

The ISIs ODC bits were reporting ST1/ST2 isolation to be off for ETMX/ETMY whereas the isolation was on. This was due to the "Correct Gain" setting to be wrong for all DOFs in the ISO filter bank. They were corrected for ETMy and ETMx. At the same time ETMX and ETMY suspensions M0 and R0 ODC damp state were also updated.

A safe.snap should be done on ETMx/ETMy ISI/SUS before next model restart.

Comments related to this report
arnaud.pele@LIGO.ORG - 15:44, Tuesday 24 June 2014 (12469)

sus/isi snap files were saved and commited under the svn.