Particle counts taken in HAM 2 during the day
Start of the morning work day reading taken in cleanroom:
0.3um........90 counts
0.5um.....40 counts
0.7um...20 counts
1.0 um....10 counts
Remainder...zero
Start of morning work day reading taken in chamber
0.3um.....20 counts
Remainder...zero
End of morning session reading taken in chamber
0.3um...180 counts
0.5um.....100 counts
0.7um....70 counts
1.0um....40 counts
2.0um.....40 counts
5.0 um...20 counts
Start of afternoon session, readings taken in cleanroom
Everything....zero counts
Start of afternoon session reading taken in chamber
0.3um....50 counts
0.5um....10 counts
End of afternoon session, reading taken in chamber
0.3um...70 counts
0.5um....50 counts
0.7um.....30 counts
1.0um...20 counts
Remainder.....zero