Reports until 18:18, Thursday 26 June 2014
H1 General
matthew.heintze@LIGO.ORG - posted 18:18, Thursday 26 June 2014 (12506)
HAM2 particle counts Thurs 26th

Particle counts taken in HAM 2 during the day

Start of the morning work day reading taken in cleanroom:

0.3um........90 counts

0.5um.....40 counts

0.7um...20 counts

1.0 um....10 counts

Remainder...zero

 

Start of morning work day reading taken in chamber

0.3um.....20 counts

Remainder...zero

 

End of morning session reading taken in chamber

0.3um...180 counts

0.5um.....100 counts

0.7um....70 counts

1.0um....40 counts

2.0um.....40 counts

5.0 um...20 counts

 

Start of afternoon session, readings taken in cleanroom

Everything....zero counts

 

Start of afternoon session reading taken in chamber

0.3um....50 counts

0.5um....10 counts

 

End of afternoon session, reading taken in chamber

0.3um...70 counts

0.5um....50 counts

0.7um.....30 counts

1.0um...20 counts

Remainder.....zero

Images attached to this report