Reports until 17:38, Saturday 28 June 2014
H1 General
rainer.weiss@LIGO.ORG - posted 17:38, Saturday 28 June 2014 (12526)
Results from the accumulation on Y2 made June 10, 2014
K. Ryan, J. Worden, R. Weiss
The report is attached below. The upper limit for the air leak rate into Y2 is Q = 1.12e-8 torr liters/sec.
The hydrogen outgassing rate at 23C is J= 2.13 e -14 torr liters/sec cm^2,  consistent with the value measured in 2000.
Non-image files attached to this report