Morning Mtg

No change anticipated to corner station laser hazard configuration today.

Matt H/Corey - Continuing ISS prep work

HAM3 - ongoing work with 532 nm fiber-coupled laser (Kiwamu/Sheila)

ITMX - alignment looks ok...need to check Arnaud's TFs from last night

Jason may need to review ITMX alignment

EX - TCS will transition to laser hazard, finish populating the HWS section of ISCTEX and do some alignment work with the ALS laser

Richard M investigating heat concerns with racks at end stations

Calum presentation on contamination control

       -MEMO regarding particle counters T1400024

       -Tree showing where to start with contamination control knowledge E1400029

Comments related to this report
calum.torrie@LIGO.ORG - 15:30, Monday 30 June 2014 (12548)

Follow up on note with some additional information than that posted by Justin Bergman re: talk by Calum on Contamination Control on Friday 27th June at LHO.

1) LIGO-T1400024: Airborne Particle Counters (Handheld) - General Instructions and LIGO use

Jeff has now got 3 to 4 hand-held particle counters avaailble for sign out at the contamination area (on our right as you walk down Dycem flooring towards LVEA from cleaning area). An additional 4 unit are on order (2x for hand-held use and 2x to replace broken plumbed in units.) Convert and report all numbers collected in particles per cubic foot (#/ft3), or particles per cubic meter (#/m3) of air sampled. Jeff has the hand-held particles counters set to display particles per cubic foot (#/ft3) i.e. the paticle counter is taking care of the conversion etc ... Just to be sure please include a picture (when you can) of the particle counter screen.

 

2) LIGO-E1400029: LIGO, Contamination Control Training Material

Level 1 and level 2 are required reading. Most if not all of you have read these at some point. While this will be compulsory for all new staff and a refresher course will be offered soon if you feel you are in need of some additional guidance now please read and review the following: -

LEVEL I General Entry Cert to access any clean room space- All workers
LIGO-E0900047: LIGO Contamination Control Plan (PAGES 1 THROUGH 27 ONLY.)

LEVEL II Chamber Entry - in chamber workers
All documents in section I above plus
LIGO-E1201035: aLIGO Chamber Entry & Exit Procedures &
LIGO-T1400024: Particle Counters - Technical Note on How to use in the field

If you wanted to check agasint what you have just read you could also have a go at our quiz, see: -

LIGO-T1400177: aLIGO Contamination Control Quiz