[Mark Arnaud]
as reported on thursday, sustools.py has been updated in order to account for the new IOP wd state channel names.
By typing in the command line :
/opt/rtcds/userapps/release/sus/common/scripts/./sustools.py -o ETMX wdNames
The output returns all wd state channel names associated with this suspension, including the new IOP channel name:
['H1:SUS-ETMX_R0_WDMON', 'H1:SUS-ETMX_M0_WDMON', 'H1:SUS-ETMX_L1_WDMON', 'H1:SUS-ETMX_L2_WDMON', 'H1:IOP-SUS_EX_ETMX_DACKILL', 'H1:SUS-ETMX_DACKILL']
All sus guardians will be restarted and tested tomorrow
By doing this change (adding "ifo-rooted" iop channels), guardian machine ran into a memory issue, similarly as few months ago with ISI guardians.
Without going into details, we basically reverted the upgrade, meaning that guardian won't look at iop wd until further notice.
All sus guardians were restarted.