Since we got the "All Clear" from SUS this morning on ITMx suspension health, the following are the final alignment numbers for the ITMx and CPx. For ACB final alignment numbers see alog 12542.
ITMx
-
X Axis Position: 5012.6 mm
-
Target: 5012.9 mm
-
Error: -0.3 mm
-
Tolerance: ±3.0 mm
-
Y Axis Position: -199.8 mm
-
Target: -200.0 mm
-
Error: +0.2 mm
-
Tolerance: ±1.0 mm
-
Z Axis Position: -83.1 mm
-
Target: -83.1 mm
-
Error: 0.0 mm
-
Tolerance: ±1.0 mm
-
Pitch: 574 µrad down
-
Target: 619 µrad down
-
Error: 45 µrad up
-
Tolerance: ±50 µrad
-
Yaw: 17 µrad CW
-
Target: 0 µrad
-
Error: 17 µrad CW
-
Tolerance: ±50 µrad
CPx
-
Pitch: 2.043 mrad down
-
Target: 1.945 mrad down
-
Error: 98 µrad down
-
Tolerance: ±1.4 mrad
-
Yaw: 533 µrad CW
-
Target: 0 µrad
-
Error: 533 µrad CW
-
Tolerance: ±1.4 mrad