Displaying report 1-1 of 1.
Reports until 16:41, Wednesday 09 July 2014
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:41, Wednesday 09 July 2014 - last comment - 09:29, Thursday 10 July 2014(12682)
WHAM4 ISI TFs running on opsws0

Pulled the covers away from the ISI table.  Attempted to close position loops on HEPI but was not stable in horizontal, decided to leave it off.  After I got the TFs started, I looked again and found the HP L4C blend filter off so this signal was getting through and I'll guess is the problem.  Don't want to stop the TF so I'll check that tomorrow.

Comments related to this report
hugh.radkins@LIGO.ORG - 09:29, Thursday 10 July 2014 (12687)

After turning on the HP (horizontal pringle) L4-C filter, the position loops work just fine.