Displaying report 1-1 of 1.
Reports until 16:28, Thursday 10 July 2014
H1 SYS
travis.sadecki@LIGO.ORG - posted 16:28, Thursday 10 July 2014 - last comment - 13:50, Friday 11 July 2014(12695)
PR3 OpLev Scatter

While assessing the IMC alignment for SR work, we (Kissel, Kiwamu, me) noticed a significant amount of scattered light from the transmitted part of the PR3 OpLev beam.  See photos.  It looks to be a bit low of center on PR3 and is scattering off a nice shiny round aluminum piece in the MC REFL periscope directly behind PR3.  Looking for advice on what to do about it.

Images attached to this report
Comments related to this report
matthew.heintze@LIGO.ORG - 17:07, Thursday 10 July 2014 (12699)

I also noticed that last week when I was up there, and we noticed this at LLO also and unfortunately it seems that all the op lev mirrors appear to transmit  some % of HeNe light (I wont go into details as to why),  and after much round discussion when we were closing up at LLO (we discussed putting black glass behind every optic) it was decided to just leave as is at LLO. We dont seem to have run into any problems because of it.

michael.vargas@LIGO.ORG - 13:50, Friday 11 July 2014 (12712)

Matt is referencing Bug-108.

Displaying report 1-1 of 1.