Weekly PSL Check
Laser
Laser is ON
Watchdog is ACTIVE
SYSSTAT shows a
RED
"LRA out of range" (LRA = Long Range Actuator). Peter King was notified.
PMC
Locked 2days8hrs (should be days/weeks)
Reflected power is 3.9W (which is
17%
of the Transmitted [22.4W] Power)
FSS
Locked 2days 8hrs (should be days/weeks)
Trans PD is 1.04 V (should be atleast 0.9V)
ISS
AOM Diffracted Power = 6.3% (should be around 10%)
Last Saturation Event was 2+ days ago