Reports until 10:07, Tuesday 15 July 2014
H1 AOS (INS, SUS)
jason.oberling@LIGO.ORG - posted 10:07, Tuesday 15 July 2014 (12750)
WBSC1 ITMy Alignment
IAS: D. Cook, J. Oberling
SUS: B. Weaver, T. Sadecki
 
After yesterday's alignment work, we did one final check on the ITMy this morning before the hand off for the output arm work.  The ITMy alignment errors are currently:

It should be noted that the pitch is without the 352 µrad correction for the First Contact currently on the HR face of the ITMy; this will have to be corrected for after the output arm work, in addition to the yaw and the X axis position.  Also, I applied a +40 yaw bias to the ITMy.  This zeros the yaw in our alignment equipment (the current slider calibration is a little off).