Rolf, Jamie, Jonathan, Jeff, Dave
We built h1susetmy against the latest branch-2.9 RCG. Initially we had compile errors, which we tracked down the ODC_CHAN.mdl file (we backed up that file and reverted from svn).
Running both the front end and the CSS diagnostics, we tested them in finding differences between the running configuration and the snap file. Several items were observed and have been resolved. Tomorrow morning we will determine the set of monitored channels (those not being controlled by guardian) for a quad suspension.
ETMY status for tonight: