WHAM3 IS Rebalanced ready for TFs

Rebalanced the ISI and ended up removing 0.8lbs and moving other.  Not too bad and a well within spec lock/unlock with worst shift of ~400counts (1600 spec.)

The ISI is unlocked and SUS has now unlocked the SUSes and we'll set up for TFs tonight.

Oh yeah--Dusts               0.3          0.5

Clean room before         0             0

Chamber  Before Work  270       130

Chamber After Work       1200        430

Comments related to this report
matthew.heintze@LIGO.ORG - 16:50, Friday 18 July 2014 (12853)

MC2 and PR2 suspensions unlocked. I damped the suspensions as I walked out of the VEA. Over to SEI for testing